www.balluff.com
9
english
3
Overview of IO-Link Data and Functions (continued)
3.2
Device Variants
Variant
Device ID
Baud rate
No. of
PDInput
No. of
PDOutput
IO-Link protocol
version
Minimum cycle
time
Variant 1
0x040C02
COM3 (230.4 kbit/s)
1 byte
1 byte
1.1.2
3 ms
Variant 2
0x040C0D
COM3 (230.4 kbit/s)
1 byte
1 byte
1.1.2
3 ms
Variant 3
0x040C0E
COM3 (230.4 kbit/s)
17 bytes
1 byte
1.1.2
5 ms
Variant 4
0x040C0F
COM3 (230.4 kbit/s)
6 bytes
1 byte
1.1.2
5 ms
Variant 5
0x040C12
COM3 (230,4 kbit/s)
17 bytes
1 byte
1.1.2
5 ms
Tab. 3-1: Device Variants
3.3
Process Data Profiles
Setting the process data profile is described in section 6.7
Process Data Info and Configuration
3.3.1 Variant 1 (AdSS)
PDInput
Byte 0
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reserved
SSC1 (ADSS1)
PDOutput
Byte 0
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reserved
Transducer
Enable
3.3.2 Variant 2 (LSSC)
PDInput
Byte 0
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
System Err
or
Reserved
Reserved
Signal
Quality Bad
Reserved
Reserved
SSC2 (LSSC2)
SSC1 (LSSC1)
PDOutput
Byte 0
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reserved
Transducer
Enable
BOS R080K-UIM-RE10-…
Photoelectric Sensors
Summary of Contents for BOS R080K-UIM-RE10 Series
Page 1: ...deutsch IO Link Konfiguration english IO Link Configuration BOS R080K UIM RE10...
Page 2: ...www balluff com...
Page 3: ...BOS R080K UIM RE10 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 107: ...BOS R080K UIM RE10 IO Link Configuration english...
Page 108: ...www balluff com...
Page 211: ......