44
english
4
Primary Device Functions (continued)
Fig. 4-14:
Light
Energy
Teach-in 100% reference
Decreasing light energy signal
– Sensor soiled
100 % Reference
Adapted Energy Signal
Switching Threshold SP1
Current Receiver Level
Signal
Quality
Signal quality – Mathematics/Algorithm
4.8.3 Process Data
Object ID
Name
Description
Direction
0x0020 (32)
Current Signal Quality
Output of the current signal quality in percent
steps from 0 % to 100 %.
Input
0x0021 (33)
Signal Quality Bad
Output of the current signal quality evaluation;
TRUE means a signal quality below the threshold
value, FALSE means a signal quality equal to or
above the threshold value.
Input
Tab. 4-27: Signal quality – process data
BOS R080K-UIM-RE10-…