SSC X Configuration
This ISDU is used to configure the SSC. It is possible to
set the switching logic, switching mode as well as the
hysteresis.
If the switching mode is changed, the setting of the
setpoint parameter can be adjusted:
– If changing from Two-Point or Window Mode to Single-
Point Mode, setpoint 2 is set to 0x7FFC and thereby
deactivated. In this state or in this setting, the setting of
setpoint 2 cannot take on any other value.
– If changing from Single-Point Mode to Two-Point oder
Window Mode, setpoint 2 is again activated and set to
the value of setpoint 1 minus the minimum hysteresis
and, in the subsequent process, can be taught to a
different value.
Value
Meaning
Description
Switchpoint Logic
0x00 (0)
High active
0x01 (1)
Low active
Switchpoint Mode
0x00 (0)
Deactivated
Switching channel
deactivated
0x01 (1)
Single Point
Single-Point Mode (SP1
activated)
0x02 (2)
Window
Window Mode (SP1 +
SP2 activated)
0x03 (3)
Two Point
Two-Point Mode (SP1 +
SP2 activated)
Switchpoint Hysteresis
0x0000…
0x000A
(0…10)
– Minimum: 0 (0x0000)
– Maximum: 10 (0x000A)
– Default: 5 (0x0005)
The hysteresis is used as
an integer offset to the
switching point value.
The value is interpreted
as a percentage with
respect to the taught-in
100 % reference. The
value 0 corresponds to a
hysteresis of 1 %.
Tab. 4-15: Switching profiles – SSC Configuration Logic
4
Primary Device Functions (continued)
4.3.6 System Commands
Command Value Device Action
0x40 (64)
Teach Apply
– Calculates the
switching point for SP1, SP2.
0x41 (65)
Teach SP1
– Determines teach
point 1 for setpoint 1 and calculates
the switching point.
0x42 (66)
Teach SP2
– Determines teach
point 1 for setpoint 2 and calculates
the switching point
1)
0x43 (67)
Teach SP1 TP1
– Determines teach
point 1 for setpoint 1
0x44 (68)
Teach SP1 TP2
– Determines teach
point 2 for setpoint 1
0x45 (69)
Teach SP2 TP1
– Determines teach
point 1 for setpoint 2
1)
0x46 (70)
Teach SP2 TP2
– Determines teach
point 2 for setpoint 2
1)
0x47 (71)
Teach SP1 Start
– Starts dynamic
teach-in for setpoint 1
0x48 (72)
Teach SP1 Stop
– Stops dynamic
teach-in for setpoint 1 and
calculates the switching point.
0x49 (73)
Teach SP2 Start
– Starts dynamic
teach-in for setpoint 2
1)
0x4A (74)
Teach SP2 Stop
– Stops dynamic
teach-in for setpoint 2 and
calculates the switching point
1)
0x4E (78)
Teach Reset
– Any active teach-in
process is interrupted, all
temporarily stored values are reset.
0x4F (79)
Teach Cancel
– Any active teach-in
process is interrupted.
1)
Not available for AdSS. Available for LSSC if the currently set mode
supports 2 setpoints.
Tab. 4-16: Switching profiles – System Commands
For an overview of all System Commands, see section 3.5
4.3.7 Events
Event
Code
Event
Type
Description
Device
Status
0x8DC0
(36288)
Notifica-
tion
Teach-in Timeout
–
The current teach-in
process took too long
and was interrupted.
0 – Device
is
operating
properly.
Tab. 4-17: Switching profiles – Events
BOS R080K-UIM-RE10-…
Photoelectric Sensors
Summary of Contents for BOS R080K-UIM-RE10 Series
Page 1: ...deutsch IO Link Konfiguration english IO Link Configuration BOS R080K UIM RE10...
Page 2: ...www balluff com...
Page 3: ...BOS R080K UIM RE10 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 107: ...BOS R080K UIM RE10 IO Link Configuration english...
Page 108: ...www balluff com...
Page 211: ......