64
english
Statistics Data Output: Status
Bit
position
Meaning
Description
0
Configured
1 – all inputs are configured
1
Started Min/
Max/Avg
1 – Min/Max/Avg running
2
Started Moving
Average
1 –
Moving Average
running
3
Buffer Overflow
Event
1 – buffer overflow
4
Timeout Event
1 – the set time for the
minimum value/maximum
value/average calculation
has elapsed
5
Reserved
–
6
Reserved
–
7
Reserved
–
Tab. 5-29: Statistics Data Output – Status
5.5.5 System Commands
Command Value Device Action
0xA7 (167)
Statistics Reset
– Resets all output
parameters to 0 and all user
settings to the default values.
0xA8 (168)
Statistics Start Min/Max/Avg
–
Starts the statistics of the minimum
value/maximum value/average
calculation.
0xA9 (169)
Statistics Stop
– Stops statistics
operation completely.
0xAC (172)
Statistics Start Moving Average
– Starts the statistics of the moving
average calculation.
Tab. 5-30: Basic statistics – System Commands
For an overview of all System Commands, see section 3.5
5
Secondary Device Functions (continued)
BOS R080K-UIM-RE10-…
Photoelectric Sensors
Summary of Contents for BOS R080K-UIM-RE10 Series
Page 1: ...deutsch IO Link Konfiguration english IO Link Configuration BOS R080K UIM RE10...
Page 2: ...www balluff com...
Page 3: ...BOS R080K UIM RE10 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 107: ...BOS R080K UIM RE10 IO Link Configuration english...
Page 108: ...www balluff com...
Page 211: ......