54
english
Speed Monitoring State
With
Speed Monitoring State
, the current status can be
read.
Value
Meaning
Description
0x00 (0)
Idle
No speed value yet available
0x01 (1)
Too low
Speed value is less than the
lower threshold
0x02 (2)
Ok
Speed value is in the suitable
range
0x04 (4)
Too high
Speed value is greater than
the upper threshold
0x08 (8)
Startup
Delay
Startup delay currently
running
0xFF (255) Deactivated
Feature is deactivated
Tab. 5-14: Signal Speed Monitoring – Speed Monitoring State
Speed Monitoring Value
With
Speed Monitoring Value
, the current speed value can
be read.
5.3.5 System Commands
Command
Value
Device Action
0x81 (129)
Application Reset
– Resets writable
parameters to the default value.
0x82 (130)
Reset Factory Settings
– Resets writable
parameters to the default value.
0xAA (170)
Signal Speed Monitoring Reset
– Resets
the speed value and flags.
Tab. 5-15: Signal Speed Monitoring – System Commands
For an overview of all System Commands, see section 3.5
5.3.6 Events
Event Code
Event Type Description
Device Status
0x8D08 (36104)
Warning
Speed value is below the limit.
0 – Device is operating properly.
0x8D09 (36105)
Warning
Speed value is above the limit.
0 – Device is operating properly.
Tab. 5-16: Signal Speed Monitoring –Events
5.3.7 Variant Dependence
The functionality is available in all variants.
5
Secondary Device Functions (continued)
BOS R080K-UIM-RE10-…
Photoelectric Sensors
Summary of Contents for BOS R080K-UIM-RE10 Series
Page 1: ...deutsch IO Link Konfiguration english IO Link Configuration BOS R080K UIM RE10...
Page 2: ...www balluff com...
Page 3: ...BOS R080K UIM RE10 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 107: ...BOS R080K UIM RE10 IO Link Configuration english...
Page 108: ...www balluff com...
Page 211: ......