www.balluff.com
31
Teach-In
1.
Use
Tl Select
to select the desired switching signal (1
to 4).
2.
Move the head to the turn-on position.
3.
Execute the
Single Value Teach SP1
(0x41) command
4.
Move the head to the turn-off position.
5.
Execute the
Single Value Teach SP2
(0x42) command
You can check your steps using the
Teach-In
Result
parameter.
7.5.3 Output configuration
Both BML outputs can be configured.
Index
Subindex
Name
Size
Access
Values
Output Type
0x00B4 (180)
1
Out 1
1 byte
Read/Write 0 = Disabled
1 = PNP (default)
2 = NPN
3 = Push-Pull
2
Out 2
1 byte
Read/Write 0 = Disabled
1 = PNP (default)
2 = NPN
3 = Push-Pull
Tab. 7-10: Output configuration
7.5.4 Diagnostics suppression
If diagnostics functions cause problems in the application,
these functions can be suppressed.
For diagnostic events implemented in the BML see
Index
Subindex
Name
Size
Access
Values
Diagnosis
Suppression
Configuration
0x00F8 (248)
1
Suppression Level
1 byte
Read/Write 0 = All events active (default)
1 = Messages suppressed
2 = Messages and warnings suppressed
3 = All events suppressed
2
PD Invalid Suppression 1 byte
Read/Write 0 = PD Invalid active
1 = PD Invalid suppressed
Tab. 7-11: Diagnostics suppression
7
IO-Link Smart Sensor profile Ed. 2 (BML SL1-ALZ1-UE/MZZ-_U1L-…) (continued)
BML SL1-ALZ _-_ _ ZZ- _ _ _ _ - _ _ _ _
Absolute Magnetically Coded Position Measuring System
english
Summary of Contents for BML SL1-ALZ-ZZ Series
Page 2: ...www balluff com...
Page 3: ...deutsch Betriebsanleitung BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 4: ...www balluff com...
Page 53: ...english User s Guide BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 54: ...www balluff com...
Page 103: ...fran ais Notice d utilisation BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 104: ...www balluff com...
Page 153: ...italiano Manuale d uso BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 154: ...www balluff com...
Page 203: ...espa ol Manual de instrucciones BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 204: ...www balluff com...
Page 253: ......