www.balluff.com
23
6
IO-Link-Smart Sensor Profile (BML SL1-ALZ0-U1ZZ-…) (continued)
6.5.5 Process data structure (PD Input Descriptor)
This parameter describes the composition of the process
data variables used.
BML SL1-… processes the process data variable as
follows:
Subindex
Values
Description
0x01
0x03
0x20
0x00
Signed Integer
32 bit length
0 bit offset
Tab. 6-6: Process data structure
6.5.6 Diagnostic data
Index
Subindex
Parameters
Size
Access
Values
0x0028 (40) 0
Process Data Input
4 bytes
Read Only
This parameter contains the current position value
or the last position value before an error occurred.
Tab. 6-7: Diagnostics parameters
6.6
Error messages
The following error messages are stored for failed
parameterization:
Error code
Error message
0×8011
Index not available
0×8012
Subindex not available
0x8020
Service temporarily not available
0×8030
Value out of range
0×8033
Parameter length overrun
0×8034
Parameter length underrun
0×8036
Function temporarily unavailable
Tab. 6-8: IO-Link specification error messages
BML SL1-ALZ _-_ _ ZZ- _ _ _ _ - _ _ _ _
Absolute Magnetically Coded Position Measuring System
english
Summary of Contents for BML SL1-ALZ-ZZ Series
Page 2: ...www balluff com...
Page 3: ...deutsch Betriebsanleitung BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 4: ...www balluff com...
Page 53: ...english User s Guide BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 54: ...www balluff com...
Page 103: ...fran ais Notice d utilisation BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 104: ...www balluff com...
Page 153: ...italiano Manuale d uso BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 154: ...www balluff com...
Page 203: ...espa ol Manual de instrucciones BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 204: ...www balluff com...
Page 253: ......