20
6.5
Parameter data
Index
Subindex
Parameters
Size
Access
Data Storage
Compatibility
mode
PDV (Process Data Value)
0x00C1 (193) 0
Offset
4 bytes Read/Write
X
X
0x00C2 (194) 0
Preset
4 bytes Read/Write
X
0x00C3 (195) 0
Output Characteristics
1 byte Read/Write
X
0x00C4 (203) 0
Minimal Negative Position
4 bytes Read/Write
X
System parameters
0x0003 (3)
0, 1, 2, 3, 4, 5 Data Storage
72 bytes Read/Write
X
0x000C (12)
0
Device Access Locks
2 bytes Read/Write
X
X
0x000D (13)
0, 1, 2, 3
ProfileCharacteristic
6 bytes Read Only
X
0x000E (14)
0, 1
PD Input Descriptor
3 bytes Read Only
X
Tab. 6-2: Parameter data of IO-Link interface
Access to subindex 0 addresses the entire
object of an index. Access of subindices > 0
addresses the individual elements of an index.
6.5.1 Process Data Configuration
The parameters can mutually influence each
other. Therefore it is recommended to make the
setting in the following sequence:
Output
Characteristics
,
Offset/Preset Teach
,
Minimal
Negative Position
.
Output Characteristics
As shipped, when moving the sensor in the direction of the
arrow the position count is positive. The count direction
can be reversed using the parameter
Output
Characteristics
. The count direction should be set before
the offset, since it may no longer be valid after changing
the offset. If the direction needs to be changed again after
setting the offset, the offset should generally be adjusted
again.
Offset, Preset, Teach In Zero Point
The beginning of the magnetic tape does not represent the
measured position 0, but rather the zero point can be at
any desired position within or outside of the magnetic tape.
Crossing the zero point causes a position jump (overrun). If
this overrun is not desired, the position of the zero point
can be changed using an offset or extending the
on
6
IO-Link-Smart Sensor Profile (BML SL1-ALZ0-U1ZZ-…) (continued)
Fig. 6-1:
Offset set
Overflow
Position value
Position value
Path
Path
Offset not set
8.19 m
8.19 m
Example for adjusting the measuring range by setting the
offset
BML SL1-ALZ _-_ _ ZZ- _ _ _ _ - _ _ _ _
Absolute Magnetically Coded Position Measuring System
english
Summary of Contents for BML SL1-ALZ-ZZ Series
Page 2: ...www balluff com...
Page 3: ...deutsch Betriebsanleitung BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 4: ...www balluff com...
Page 53: ...english User s Guide BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 54: ...www balluff com...
Page 103: ...fran ais Notice d utilisation BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 104: ...www balluff com...
Page 153: ...italiano Manuale d uso BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 154: ...www balluff com...
Page 203: ...espa ol Manual de instrucciones BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Page 204: ...www balluff com...
Page 253: ......