Secondary Device Functions (continued)
5.9.5 System Commands
Command Value Device Action
0x81 (129)
Application Reset
– Resets the
Voltage Monitoring Detection Time
Duration
with ISDU-index 0x2200 to
the default value 10.
0x82 (130)
Reset Factory Settings
– Resets the
Voltage Monitoring Detection Time
Duration
with ISDU-index 0x2200 to
the default value 10.
Tab. 5-42: Voltage and current monitoring – System Commands
For an overview of all System Commands, see section 3.5
5.9.6 Events
Event Code
Event Type
Description
Device Status
0x5110
(20752)
Warning
Primary supply voltage exceeded
►
Check for deviations in the supply.
2 – Out-of-Specification
0x5111
(20753)
Warning
Primary supply voltage below minimum value
►
Check for deviations in the supply.
2 – Out-of-Specification
0x8D0B
(36107)
Warning
Overload or short circuit at pin 2
►
Check wiring.
2 – Out-of-Specification
Tab. 5-43: Voltage and current monitoring – Events