Secondary Device Functions
5.1
External Signal Blanking
5.1.1 Description
External signal blanking reduces the sensitivity to
interfering signals in the surrounding area. Interference is
filtered out.
This function allows influence from a given installation
situation to be reduced e.g. a switching interval offset
resulting from the ambient conditions. The function can be
activated and deactivated as required. The offset is
recorded and compensated for upon every reactivation.
For this reason, no damping material should be positioned
in front of the active surface when the function is activated.
Since the influence can be highly variable in any given
case, a data storage function is not available.
5.1.2 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data Storage
Default
External Signal Blanking 0x0421 (1057)
0
R/W
1 byte
UINT8(ENUM)
No
0
Tab. 5-1: External signal blanking – ISDU
External Signal Blanking
The function can be activated and deactivated via the
External Signal Blanking
parameter.
Value
Meaning
Description
0x00 (0) Deactivated
External signal blanking off
0x01 (1) Activated
External signal blanking on
Tab. 5-2: External signal blanking – Activate/deactivate
5.1.3 System Commands
Command
Value
Device Action
0x81 (129)
Application Reset
– Resets writable
parameters to the default value.
0x82 (130)
Reset Factory Settings
– Resets writable
parameters to the default value.
Tab. 5-3: External signal blanking – System Commands
For an overview of all System Commands, see section 3.5
5.1.4 Variant Dependence
The functionality is available in all variants.
BES M08EH1-L01C20B-S04G-L04 /BES M12E_1-L01C_0_-S04G-L04 /