www.balluff.com
31
english
Setpoint 2 Adjustment Mode (only for LSSC profile)
The
Setpoint 2 Adjustment
mode is available in Two Point
Switch Mode and in Window Mode of the LSSC profile.
System Command
Switch mode
Two-point mode
Window Mode
Fine Adjust near
High
SP1
SP2
Low
Measurement value
Switching output
High
SP1
SP2
Low
Measurement value
Switching output
Fine Adjust far
High
Low
SP1
SP2
Measurement value
Switching output
High
SP1
SP2
Low
Measurement value
Switching output
Tab. 4-7: Fine Adjustment – Setpoint 2 Adjustment Mode (only for
LSSC profile)
Manual Teach-in
In addition to the IO-Link-controlled teach processes, there
is the possibility of a manual teach-in. This is, in principle, a
Singe-Value Teach of setpoint 1 in the Single-Point
switching mode. With this process, only SSC 1 can be
taught. The teach process is started with the rising edge
on Pin 2. The now-active teach process is indicated by
illumination of the red LED.
If the LED switches off, the teach process has been ended
successfully. The sensor or SSC1 is now in Single-Point
Mode, the new setpoint is used as switching point in
combination with the standard hysteresis. The previous
configuration is discarded.
If the LED flashes for 3 seconds, the teach process was
not ended successfully. In this case, the previous
configuration continues to be used. The following error
causes are possible:
– The current measurement value is outside of the
validity range.
– The sensor cannot be parameterized locally. The
reasons for this are currently active ISDU
communication, an active block parameterization or set
access locks.
It is recommended that the manual teach process
only be used with inactive IO-Link communication
(in SIO modus).
4
Primary Device Functions (continued)
BES M08EH1-L01C20B-S04G-L04 /BES M12E_1-L01C_0_-S04G-L04 /
BES M18EH1-L01C_ _ _-S04G-L04
Inductive sensors
Summary of Contents for BES M08EH1-L01C20B-S04G-L04
Page 2: ...www balluff com ...
Page 4: ...www balluff com ...
Page 98: ......
Page 100: ...www balluff com ...