5.5.4 ISDU
Minimum
,
Maximum
,
Average
and
Moving
Average outputs
are output in FLOAT32 format.
Before they are processed further and converted
from FLOAT32 to INT32 or UINT32, the output
signal must be checked to determine whether it
is larger than INT32_Max or UINT32_Max. If it is
larger, data type UINT64 or INT64 should be
used.
Name
Index
Subindex
Access
Length
Data Type
Data
Storage
Default
Statistics Data Configuration
0x0426
(1062)
0
R/W
8 byte
Yes
Input Signal
1
R/W
2 bytes
UINT16(ENUM)
No
0
Time Period Unit
2
R/W
1 byte
UINT8(ENUM)
No
Seconds
Time Period Value
3
R/W
2 bytes
UINT16
No
1
Moving Average Window
Unit
4
R/W
1 byte
UINT8(ENUM)
No
Measurement
values
Moving Average Window
Value
5
R/W
2 bytes
UINT16
No
100
Statistics Data Output
0x0427
(1063)
0
R
21 Byte
n/a
Minimum
1
R
4 byte
FLOAT32
n/a
–
Maximum
2
R
4 byte
FLOAT32
n/a
–
Average
3
R
4 byte
FLOAT32
n/a
–
Moving Average
4
R
4 byte
FLOAT32
n/a
–
Number Of Samples
5
R
4 byte
UINT32
n/a
–
Status
6
R
1 byte
UINT8
n/a
–
Tab. 5-21: Basic statistics – ISDU
Statistics Data Configuration: Input Signal
All data types of process data objects can be used for
input configuration, with the exception of Boolean. The
respective Object IDs can be found in the respective
section on the function. Default value is 0, this corresponds
to “no object”.
5
Secondary Device Functions (continued)
BES M08EH1-L01C20B-S04G-L04 /BES M12E_1-L01C_0_-S04G-L04 /
BES M18EH1-L01C_ _ _-S04G-L04
Inductive sensors
Summary of Contents for BES M08EH1-L01C20B-S04G-L04