www.balluff.com
69
english
5
Secondary Device Functions (continued)
Device Temperature
Device Temperature
contains information about the device
temperature (current value in °C), the minimum or
maximum device temperature since the last time the
device was switched on/reset (in °C) and minimum or
maximum device temperature during the lifetime of the
device (in °C).
Device Temperature Alarm Configuration
Setting for the lower threshold value (in °C) for the device
temperature warning (0x8D20) and upper threshold value
(in °C) for the device temperature warning (0x8D10).
5.11.4 Events
Event Code
Event Type Description
Device Status
0x4000 (16384) Error
Temperature Fault – Overload
– The device is operated
outside of the device-specific temperature limits. Risk
of device damage.
4 – Failure
0x4210 (16912) Warning
Device Temperature Overrun – Clear Heat Of Source
– Risk of device damage. The device is too hot.
►
Remove heat source, provide the device with heat
insulation if necessary.
2 – Out-of-Specification
0x4220 (16928) Warning
Device Temperature Underrun – Insulate Device
– Risk
of device damage. The device is too cold.
►
Insulate the device.
2 – Out-of-Specification
0x8D10 (36112) Warning
Device Temperature Upper Warning
– The set upper
temperature warning threshold has been exceeded.
0 – Device is operating properly.
0x8D20 (36128) Warning
Device Temperature Lower Warning
– The set lower
temperature warning threshold is below the minimum
value.
0 – Device is operating properly.
Tab. 5-51: Internal temperature – Events