www.balluff.com
13
english
Name
Index
Sub-
index
Access
Length
Data Type
Data
Storage
Default
Switching profiles (LSSC)
Fine Adjust Config
0x0056
(86)
0
R/W
2 bytes
No
–
Channel
1
R/W
1 byte
UINT8
No
0x00
Mode
2
R/W
1 byte
UINT8
No
0x00
Teach-in Select
0x003A
(58)
0
R/W
1 byte
UINT8
No
0x00
Teach-in Result
0x003B
(59)
0
R
1 byte
UINT8
No
–
SSC 1 Parameter
0x003C
(60)
0
R/W
8 byte
Yes
1)
Setpoint 1
1
R/W
4 byte
INT32
No
0x00000064 (100)
Setpoint 2
2
R/W
4 byte
INT32
No
0x7FFF FFFC
(deactivated)
SSC 1 Configuration
0x003D
(61)
0
R/W
4 byte
Yes
Switchpoint Logic
1
R/W
1 byte
UINT8
No
0x00
Switchpoint Mode
2
R/W
1 byte
UINT8
No
0x01
Switchpoint Hysteresis
3
R/W
2 bytes
INT16
No
0x19 (25)
SSC 2 Parameter
0x003E
(62)
0
R/W
8 byte
Yes
1)
Setpoint 1
1
R/W
4 byte
INT32
0x00000064 (100)
Setpoint 2
2
R/W
4 byte
INT32
0x7FFF FFFC
(deactivated)
SSC 2 Configuration
s (63)
0
R/W
4 byte
Yes
Switchpoint Logic
1
R/W
1 byte
UINT8
0x00
Switchpoint Mode
2
R/W
1 byte
UINT8
0x01
Switchpoint Hysteresis
3
R/W
2 bytes
INT16
0x19 (25)
Transducer Signal
0x01B2
(434)
0
RO
2 bytes
INT16
No
–
1)
Data storage possible for SSC parameters. Switching interval can change after sensor change.
Signal Quality
Low Signal Quality
Threshold
0x00CE
(206)
0
R/W
1 byte
UINT8
Yes
0
Signal Quality
0x00CF
(207)
0
R
2 bytes
n/a
Current Signal Quality
1
R
1 byte
UINT8
n/a
–
Signal Quality Bad
2
R
1 bit
BOOL
n/a
–
External Signal Blanking
External Signal
Blanking
0x0421
(1057)
0
R/W
1 byte
UINT8(ENUM)
No
0
3