5.4.4 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data Storage
Default
Switching Counter
0x00B6 (182)
0
R/W
6 byte
Yes
Input
1
R/W
2 bytes
UINT16(ENUM)
No
0
Mode
2
R/W
1 byte
UINT8(ENUM)
No
0
Limit
3
R/W
2 bytes
UINT16
No
2
Startup Delay
4
R/W
1 byte
UINT8
No
0
Switching Counter
Status
0x00B7 (183)
0
R
3 byte
n/a
State
1
R
1 byte
UINT8(ENUM)
n/a
–
Value
2
R
2 bytes
UINT16
n/a
–
Tab. 5-16: Switching counter – ISDU
Switching Counter Input
With
Switching Counter Input
, the internal binary signal
source can be selected.
Input
contains a list of the internal
binary signals.
Switching Counter Mode
With
Switching Counter Mode
, the current mode of the
counter function can be selected.
Value
Meaning
Description
0x00 (0) Deactivated
Deactivated
0x01 (1) Static
Static counter function
0x02 (2) Auto
Auto counter function
Tab. 5-17: Switching Counter – Switching Counter Mode
Switching Counter Limit
With
Switching Counter Limit
, the count limit for the
counter can be set. The value range is between 0x0002 (2)
and 0xFFFF (65535).
Switching Counter Startup Delay
With
Switching Counter Startup Delay
, the time for the
startup delay can be set. The startup delay begins after the
supply voltage is switched on. During the startup delay,
the counter has no function. The counter starts after the
startup delay has elapsed. The value represents the time in
seconds. The value range is between 0x00 (0) and 0xFF
(255). A value of 0x00 (0) represents no start delay.