Introduction 1-3
MN767S
1.3 Quick Start
Figure 1-1 Power & Motor Terminal Locations
See Recommended Tightening
Torques in Table 4-1.
Frame B
(VS1STS51 shown
as an example)
U V W + BR
L1/L L2/N L3
Power Up Procedure (
Refer to Chapter 3, 4 and 5 for additional details.)
1. Remove all power from the control.
2. Couple the motor to its load.
3. Verify freedom of motion of motor shaft.
4. Verify the motor coupling is tight without backlash.
5. Connect input control wires and output control wires, See Figure 1-2.
6. Connect a control switch between terminals 1 and 2 ensuring that the contact is open (drive disabled).
7. Connect Power & Motor wires to the control, See Figure 1-1.
8. Turn power on. Be sure there are no faults.
9. Set the following parameters for the values displayed on the motor nameplate:
P1-01 Motor Rated Voltage
P1-02 Motor Rated Current
P1-03 Motor Rated Frequency
P1-04 Motor Rated Speed
10. Set P1-07 Start/Stop Source to 1 or 2
11. Verify the holding brakes if any, are properly adjusted to fully release and set to the desired torque.
12. Enable the drive by closing the switch between control terminals 1 & 2.
13. Press the START key. If this is the first enable from factory default parameters, the drive will carry out an Auto tune as
described in Section 6.7. On completion of the Auto tune, the display shows
.
.
14. Select and program additional parameters to suit your application, see Chapter 7.
The control is now ready for use in the keypad mode. If a different operating mode is desired, refer to Chapter 7 Parameter
Descriptions.
Summary of Contents for VS1STS Series
Page 1: ...10 11 Installation Operating Manual MN767S VS1STS AC Microdrive ...
Page 6: ...iv MN767S ...
Page 28: ...5 8 Control Wiring MN767S ...
Page 50: ...8 2 Customizing Your Application MN767S ...
Page 54: ...9 4 Troubleshooting MN767S ...
Page 56: ...A 2 Technical Specifications MN767S ...
Page 68: ...D 2 Options and Kits MN767S ...