7-10 Parameter Descriptions
MN767S
7.3.4 Parameter Group 0 – Monitoring Parameters (Read Only)
Table 7-5 Parameter Group 0 – Monitoring Parameters (Read Only)
Par
No.
Description
Range
Units
Default
P0-01
Bipolar Analog Input Value
-100 to 100
%
100% = max input voltage
P0-02
2nd Analog Input Value
0 to 100
%
100% = max input voltage
P0-03
Post Ramp Speed Reference
-500 to 500
%
100% = P1-03
P0-04
Digital Speed Reference
-P1-06 to P1-06
Hz / Rpm
Digital speed reference
P0-05
Torque Controller Reference
0 to 200
%
Torque reference set point
P0-06
PID Reference
0 to 100
%
PID reference / set point
P0-07
PID Feedback
0 to 100
%
PID controller feedback value
P0-08
PID Error
0 to 100
%
Actual PID error
P0-09
PID P Term
0 to 100
%
Proportional component
P0-10
PID I Term
0 to 100
%
Integral component
P0-11
PID D Term
0 to 100
%
Differential component
P0-12
PID Output
0 to 100
%
Output from PID controller
P0-13
Output Torque
0 to 200
%
100% = motor rated torque
P0-14
Magnetizing Current
Drive dependent
A
Motor RMS magnetizing current
P0-15
Rotor Current
Drive dependent
A
Rotor RMS current
P0-16
Field Strength
0 to 100
%
Magnetic field strength
P0-17
Stator Resistance
Drive dependent
Ohms
Phase to phase stator resistance
P0-18
Stator Inductance
Drive dependent
H
Stator inductance
P0-19
Rotor Resistance
Drive dependent
Ohms
Calculated rotor resistance
P0-20
DC Bus Voltage
0 to 1000
Volts
Internal DC Bus voltage
P0-21
Drive Temperature
0 to 120
ºC
Measured heat sink temperature
P0-22
Supply Voltage L1 – L2
Drive dependent
Volts
Phase to phase supply voltage
P0-23
Supply Voltage L2 – L3
Drive dependent
Volts
Phase to phase supply voltage
P0-24
Supply Voltage L3 – L1
Drive dependent
Volts
Phase to phase supply voltage
P0-25
Estimated Rotor Speed
Drive dependent
Hz / Rpm
Vector mode, estimated motor speed
P0-26
kWh Meter
0 to 999.9
kWh
Cumulative energy consumption
P0-27
MWh Meter
0 to 60,000
MWh
Cumulative energy consumption
P0-28
Software ID – IO Processor
Drive dependent
-
Version number & checksum
P0-29
Software ID – Motor Control
Drive dependent
-
Version number & checksum
P0-30
Drive Serial Number
Drive dependent
-
Unique drive serial number
Summary of Contents for VS1STS Series
Page 1: ...10 11 Installation Operating Manual MN767S VS1STS AC Microdrive ...
Page 6: ...iv MN767S ...
Page 28: ...5 8 Control Wiring MN767S ...
Page 50: ...8 2 Customizing Your Application MN767S ...
Page 54: ...9 4 Troubleshooting MN767S ...
Page 56: ...A 2 Technical Specifications MN767S ...
Page 68: ...D 2 Options and Kits MN767S ...