Installing the Drive 3-3
MN767S
3.3.2 Mounting Clearances
For drives mounted in ventilated enclosures or force ventilated, the following cabinet sizes are recommended.
Table 3-2 Free-Ventilated Enclosure Mounting
Drive Rating
L
W
D
G
inch
mm
inch
mm
inch
mm
inch
mm
Frame B
5 Hp
23.62
600
15.75
400
9.84
250
3.94
100
Frame C
20 Hp
31.50
800
23.62
600
11.81
300
5.91
150
Frame D
30 Hp
39.37
1000
23.62
600
11.81
300
7.87
200
Table 3-3 Force Ventilated Enclosure Mounting
Drive Rating
L
W
D
G
inch
mm
inch
mm
inch
mm
inch
mm
Frame B
5 Hp
12.60
320
7.87
200
7.87
200
2.95
75
Frame C
20 Hp
15.75
400
9.84
250
7.87
200
3.94
100
Frame D
30 - 60 Hp
31.50
800
19.69
500
9.84
250
5.12
130