5-28 Control Wiring
MN766
5.14.3 Update Firmware
Installing chx Files
(If you are installing msx fi les skip this procedure and go to “Installing msx Files”).
This procedure erases memory and restores factory settings. All user data will be lost. After the fi rmware download, all user
data values must be reprogrammed.
1. The software must be downloaded from the Baldor site: http://www.baldor.com
Simply log into that web site, Figure 5-27. Locate and click on Drive Firmware.
2. Save the fi rmware fi le to a location on your hard disk.
(for example: C:\Program Files\Mint Machine Center\Firmware\VS1 Servo\SHH_1_20.chx).
This procedure erases memory and restores factory settings. All user data will be lost. After the fi rmware download, all user
data values must be reprogrammed.
3. Start the Workbench program as before, see Figure 5-32.
a.
Select “Download Firmware” from the Tools menu.
b.
Select “Advanced” then “Download Firmware File”, click “Yes” at the warning to download.
c.
Select the fi rmware fi le to download (for example: SHH_1_20.chx).
d.
When complete, the new fi rmware version is displayed and the control is ready for use.
Note:
All user settings and motor parameter values have been over written by factory settings.
Figure 5-31 Mint WorkBench Firmware Update
a
Software version is Servo (SHH) version 1 release 20.
b
d
c
SHH-1.20
Summary of Contents for VS1SD
Page 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Page 12: ...2 2 General Information MN766...
Page 16: ...3 4 Installing the Drive MN766...
Page 108: ...7 34 Parameter Descriptions MN766...
Page 114: ...8 6 Customizing Your Application MN766...
Page 128: ...9 14 Troubleshooting MN766...
Page 154: ...12 12 Monitor and RTC Description MN766...