Monitor and RTC Description 12-1
MN766
Chapter 12
Monitor and RTC Description
12.1 Monitor Parameters (P0001 to P0818)
Monitor parameters can be viewed using the WorkBench software. Most are read only (P0001) but some (P0052) can be
written as well.
Table 12-1 Monitor Parameters Descriptions
P#
Type
Name
Unit
Help
1
SOFTWARE VERSION
Software Version. - Drive fi rmware version number
2
LOC/REM STATUS
Local/Remote Status. - Source of run/stop commands. Local for keypad
or Remote for terminal block
3
DRIVE STATUS
Drive Enable Status. - 0 for disabled, 1 for enabled
4
MOTION STATUS
Motion Status. - Status: stopped, forward, reverse, bipolar, sleep,
homing, etc.
5
MOTOR VOLTS
V
Motor Volts. - Estimated line-to-line drive output RMS voltage
6
MOTOR CURRENT
A
Motor Current. - Measured motor RMS current
7
MOTOR ABS SPEED
RPM
Motor Absolute Speed. - Estimated or measured absolute rotor speed
8
POSITION COUNTER
CNT
Position Counter. - Accumulated count in revolutions and counts for
feedback device.
9
SPEED REF
Hz
Speed Reference. - Setpoint speed for motor. Command source
parameter determines the source
10
ABS SPEED DEMAND
Hz
Absolute Speed Demand. - Absolute speed output from Speed Profi ler.
11
SPEED DEMAND
Hz
Speed Demand. - Signed speed output from Speed Profi ler
12
ABS MOTOR FREQ
Hz
Absolute Motor Frequency. - Estimated motor electrical frequency
13
MOTOR FREQ
Hz
Motor Frequency. - Signed motor frequency
14
DRIVE TEMP
°C
Drive Temperature. - Measured temperature of drive heat sink
15
BUS VOLTAGE
V
Bus Voltage. - Measured bus voltage. DC bus high fault occurs above
400/820V DC
16
OVERLOAD LEFT
%
Overload Remaining. - Current overload count remaining until overload
fault/foldback occurs
17
INPUTS
Digital Inputs. - State of terminal block digital inputs. Off/On indicated
by 0/1
18
OUTPUTS
Digital Outputs. - State of the terminal block digital/relay outputs. Off/On
indicated by 0/1
19
R/W
RATED HP
HP
Rated Horsepower. - Drive rated horsepower
20
R/W
RATED CURRENT
A
Rated Current. - Nominal/derated drive continuous RMS current rating
21
R/W
RATED PK CURRENT
A
Rated Peak Current. - Nominal/de-rated drive peak, short term, current
rating
22
R/W
RATED VOLTS
V
Rated Voltage. - Nominal voltage rating of drive
23
ACTIVE FAULTS
Active Faults. - Number of active / simultaneous drive faults
24
ACTIVE FLT CODE
Active Fault Code. - Currently active drive fault code number
25
PROC FEEDFORWARD
%
FF Process Feedforward. - Process PID feed forward signal
26
PROC SETPOINT
%
SP Process Setpoint. - Process PID set point signal
Summary of Contents for VS1SD
Page 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Page 12: ...2 2 General Information MN766...
Page 16: ...3 4 Installing the Drive MN766...
Page 108: ...7 34 Parameter Descriptions MN766...
Page 114: ...8 6 Customizing Your Application MN766...
Page 128: ...9 14 Troubleshooting MN766...
Page 154: ...12 12 Monitor and RTC Description MN766...