B-2 Parameter Tables
MN766
Block Title
Parameter
P#
Adjustable Range
Factory
User Setting
KEYPAD
SETUP
STOP KEY
1301 0-Off (Keypad Stop inactive in remote)
1-On (Keypad Stop active in remote)
1
STOP MODE
1302 0-Regen
1-Coast
0
RUN FORWARD
1303 0-Off
1-On
1
RUN REVERSE
1304 0-Off
1-On
1
SWITCH ON FLY
1305 0-Off
1-On
0
LOCAL HOT START
1306 0-Off
1-On
0
SPEED INCREMENT
1307 0 - 2500RPM or 0.01 to 60Hz
30
INIT LOCAL SPEED
1308
0-Zero
1-Last Speed
2-Set Speed
0
SET SPEED
1309 0 - MAX Speed RPM
30
PARAMS TO KEYPAD
1310 0-No
1-Yes
0
DOWNLOAD SELECT
1311 0-All
1-Motor
2-Other
0
KEYPAD TO PARAMS
1312 0-No
1-Yes
0
KEYPAD CONTRAST
1313 0 - 100% (0=dimmest, 100=brightest)
50
BACKLIGHT 1314
0-Off
1-On
1
LOC TORQUE MODE
1315 0-Off
1-On
0
LOC TORQUE REF
1316 -100.00 to 100.00%
0.00
INPUT SETUP
OPERATING MODE
1401 0-Keypad
1-Standard Run 2Wire
2-Standard Run 3Wire
3-15 Preset Speeds
4- Fan & Pump 2Wire
5- Fan & Pump 3Wire
6-Process Control
7-3Spd Ana 2Wire
8-3Spd Ana 3Wire
9-E-Pot 2Wire
10-E-Pot 3Wire
11-Network
12-Profi le Run
13-15 Preset Positions
14-Bipolar
15-Pulse Follower
16-PLC
0
COMMAND SOURCE
1402 0-None
1-Analog In1
2-Analog In2
3-Keypad
4-Network
5-Composite Ref
6-Opt1 Ana In1
7-Opt1 Ana In2
8-Opt2 Ana In1
9-Opt2 Ana In2
10-EXB Pulse Fol
1
Table B-1 Parameter Block Values Level 1 (Cont.)
Summary of Contents for VS1SD
Page 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Page 12: ...2 2 General Information MN766...
Page 16: ...3 4 Installing the Drive MN766...
Page 108: ...7 34 Parameter Descriptions MN766...
Page 114: ...8 6 Customizing Your Application MN766...
Page 128: ...9 14 Troubleshooting MN766...
Page 154: ...12 12 Monitor and RTC Description MN766...