7-30 Parameter Descriptions
MN766
Block Title
Parameter (Number)
Selection (Value)
Parameter Name and Description
PLC MODE
PLC CONFIG 1 through
PLC CONFIG 30
(3401 - 3430)
Preset Value: 000.128.000.000
Range: 0 to 255.255.255.255
30 PLC statements that defi ne the 32 bit word format and structure as:
Where:
DDD = bits 31-24 Byte 3
CCC = bits 23-16 Byte 2
BBB = bits 15-8 Byte 1
AAA = bits 7-0 Byte 0
Parameter No. Hex Byte 3 Hex Byte 2
Hex Byte 1 Hex Byte 0
PS3401 - 3430 Condition ID Logical Operator ID Condition ID Action ID
MSD
LSD
(see Chapter 10) (see Chapter 10) (see Chapter 10) (see Chapter 10)
051 = Digital Input 1 (see Chapter 10)
000 = OR (see Chapter 10)
000 = False (see Chapter 10)
020 = Forward (see Chapter 10)
Parameter Number Format = DDD.CCC.BBB.AAA Example: P3401 = 051.000.000.020
See also Chapter 10.
COMPARE A PARAM
(3431)
COMPARE B PARAM
(3433)
Preset Value: 0
Range: 00000 to 10000
Comparator parameters provide a way to monitor real-time signals
within the drive and apply them to the PLC Mode’s logic. The setting of
these parameters is the number of the parameter to be monitored by the
comparator. They may be used on the condition defi nition side of the PLC
Mode’s logic. (See Chapter 10).
COMPARE A CNST1
(3432)
COMPARE B CNST1
(3434)
Preset Value: 0.00%
Range: 0.00 to 200.00%
See Chapter 10.
COMPARE A CNST2
(3435)
COMPARE B CNST2
(3436)
Preset Value: 0.00%
Range: -100.00 to 100.00%
See Chapter 10.
TIMER A DURATION
(3440)
TIMER B DURATION
(3441)
TIMER C DURATION
(3442)
TIMER D DURATION
(3443)
Preset Value: 0.00
Range: 0.00 to 999999.00 seconds
See Chapter 10.
COMP REF
PARAM A NUMBER
(3501)
PARAM B NUMBER
(3503)
Preset Value: 0
Range: 00000 to 10000
Holds number to the second parameter used in the reference. See Chapter
11.
PARAM A FUNCTION
(3502)
PARAM B FUNCTION
(3504)
Preset Value: 0
Range: 0 - 9
Zero (0)
Identity (1)
Absolute Value (2)
Invert (3)
Square (4)
Square Root (5)
Sine (6)
Cosine (7)
Ramp Generator (8)
Freq Generator (9)
Mathematical function applied to the fi rst (A) and second (B) parameter. See
Chapter 11.
Table 7-3 Level 3 Parameter Block Defi nitions Continued
Summary of Contents for VS1SD
Page 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Page 12: ...2 2 General Information MN766...
Page 16: ...3 4 Installing the Drive MN766...
Page 108: ...7 34 Parameter Descriptions MN766...
Page 114: ...8 6 Customizing Your Application MN766...
Page 128: ...9 14 Troubleshooting MN766...
Page 154: ...12 12 Monitor and RTC Description MN766...