6-14 Using the Keypad
MN766
Diagnostics Continued
Action
Description
Display
Comments
Press
to display next
group.
Displays energy cost (based on
parameter P2305 value).
STATUS
0.00r
MAIN
ENERGY
EST POWER
0.00KW
EST ENERGY
0.0KWH
EST COST
0.0$
DIAG
STOP
LOCAL
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
Press F1 to go to Status screen.
Press
to display next
group.
Diagnostic Analog Input values
display.
STATUS
0.00r
MAIN
ANALOG INPUTS
ANA IN1
1.3v
ANA IN2
0.0v
DIAG
STOP
LOCAL
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
Press
to display next
group.
Diagnostic Analog Output values
display.
STATUS
0.00r
MAIN
ANALOG OUTPUTS
ANA OUT1
0.0V
ANA OUT2
0.0V
DIAG
STOP
LOCAL
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
or
or
or
Press to display next
group.
Displays keypad software version.
STATUS
0.00r
MAIN
KEYPAD VERSION
KEYPAD SOF 1.1X
DIAG
STOP
LOCAL
Press
to display next
group.
Diagnostic installed Option Card
identification display.
.
STATUS
0.00r
MAIN
OPTION BOARDS
OPTION 1
ETHERNET
OPTION 2
NONE
FEEDBACK
RESOLVER
DIAG
STOP
LOCAL
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
Press F1 to go to Status screen.
Press to display next
group.
Displays Composite Reference
values.
STATUS
0.00r
COMPOSITE REF
COMPONENT A
0.00%
COMPONENT B
0.00%
REFERENCE
0.00%
DIAG
STOP
LOCAL
Press to display next
group.
DC Bus Voltage
Drive Heatsink Temperature
% Drive Overload (remaining)
DRIVE
BUS VOLTAGE
333.9V
DRIVE TEMP
26.1C
DRIVE O/L L
100.0%
DIAG
STOP
LOCAL
STATUS
0.00r
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
Press
to display next
group.
Motor Voltage
Motor Current
% Motor Overload (remaining)
MOTOR
MOTOR VOLTAGE
333.9V
MOTOR CURRE
4.8A
MOTOR O/L L
100.0%
DIAG
STOP
LOCAL
STATUS
0.00r
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
or
or
or
Press to display next
group.
Full revolutions are displayed.
STATUS
0.00r
MAIN
POSITION COUNTER
REVOLUTIONS 0
COUNTS 0
SPEED MEAS 0
DIAG
STOP
LOCAL
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
or
(Note that this is not the same
as the drive control firmware.)
Alarm
MAIN
MAIN
Press F1 to go to Status screen.
Press F1 to go to Status screen.
Press F1 to go to Status screen.
Press F1 to go to Status screen.
Press F1 to go to Status screen.
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
Press F1 to go to Status screen.
or
Press
to go to the next or
previous Diagnostic screen.
Press F2 to return to main menu.
Press F1 to go to Status screen.
or
Summary of Contents for VS1SD
Page 1: ...05 13 Installation Operating Manual MN766 VS1SD AC Servo Control...
Page 12: ...2 2 General Information MN766...
Page 16: ...3 4 Installing the Drive MN766...
Page 108: ...7 34 Parameter Descriptions MN766...
Page 114: ...8 6 Customizing Your Application MN766...
Page 128: ...9 14 Troubleshooting MN766...
Page 154: ...12 12 Monitor and RTC Description MN766...