![Baldor ID5601-EO Installation And Operation Manual Download Page 43](http://html.mh-extra.com/html/baldor/id5601-eo/id5601-eo_installation-and-operation-manual_468808043.webp)
43
Symptom
Possible Cause
Suggested Solution
Motor runs then stops
after a short time.
The motor may be
overloaded.
Check the motor
current with an AC
RMS responding
ammeter. Reduce load.
The Drive Trips due
to overload
(I
2
t Fault).
The CL setting may
need to be increased.
See Section 7.6.
Verify Motor
Horsepower Jumper,
J2, is set correctly. See
Section 6.2.
The drive must be
manually restarted by
either of the following
methods:
1.
Disconnect
and reconnect the AC
power (the “ST” LED
must change from
quick flashing red to
flashing red/yellow).
2.
Set the Main Speed
Potentiometer to zero
(fully counterclockwise).
3.
Open and close the
Forward-Stop-Reverse
Switch (or contact)
or Run Switch (or
contact). See Section
6.3. Reduce load.
The Acceleration
setting may be too
fast.
Reduce the ACCEL
Trimpot setting as
described in Section
7.3.
Overvoltage Fault
Rapid Deceleration
change. Verify drive
setting. See Section
7.4.
Short circuit Fault
Verify motor condition.
Table 10-1 Troubleshooting Guide Continued
Summary of Contents for ID5601-EO
Page 18: ...18 Figure 2 3 Drive Layout ...