28
6. SETTING SELECTABLE JUMPERS
WARNING! ELECTRICAL SHOCK CAN CAUSE SERIOUS OR FATAL
INJURY. BE SURE THAT ALL POWER IS DISCONNECTED
FROM DRIVE BEFORE THE COVER IS OPENED. OPENING
OF THE COVER IS REQUIRED TO MAKE INSTALLATION
CONNECTIONS. ELECTRICAL SHOCK CAN CAUSE
SERIOUS OR FATAL INJURY IF THE COVER IS REMOVED
AND POWER IS STILL APPLIED.
The drive has customer selectable jumpers which must be set
before the drive can be used. For an overview, see Table 1-4. For
location of jumpers, see Figure 2-2.
6.1 AC LINE INPUT VOLTAGE (J1)
The drive is factory set for 208/230 Volt AC line input (Jumper J1
not installed). For 115 Volt AC line input, install Jumper J1. See
Figure 6-1.
Figure 6-1 AC Line Input Voltage Selection
208/230 Volt AC Line Input
(J1 not Installed (Factory Setting))
115 Volt AC Line Input
(J1 Installed)
2
115VAC
J1
A B
J1-A
J1
-B
11
5VA
C
J1
-A
A B
J1
-B
J1
Notes:
1. The drive is factory set for 208/230 Volt AC line input (Jumper J1 not
installed). For 115 Volt AC line input, install Jumper J1 (suppled).
2. Jumper J1 is supplied in the hardware bag.
6.2 MOTOR HORSEPOWER (J2)
Set Jumper J2 to the corresponding position for the motor being
used. See Figure 6-2.