32
7. TRIMPOT ADJUSTMENTS
The drive contains trimpots that are factory set for most
applications. See Figure 2-2 for the location of the trimpots and
their approximate factory calibrated positions. Some applications
may required readjustment of the trimpots in order to set the drive
for a specific requirement. The trimpots may be readjusted as
described.
WARNING! IF POSSIBLE, DO NOT ADJUST TRIMPOTS WITH THE MAIN
POWER APPLIED. IF ADJUSTMENTS ARE MADE WITH THE
MAIN POWER APPLIED, AN INSULATED ADJUSTMENT
TOOL MUST BE USED AND SAFETY GLASSES MUST
BE WORN. HIGH VOLTAGE EXISTS IN THIS DRIVE.
FIRE AND/OR ELECTROCUTION CAN RESULT IF CAUTION
IS NOT EXERCISED. “ALL” SAFETY WARNINGS MUST BE
READ AND UNDERSTOOD BEFORE PROCEEDING.
7.1 MINIMUM SPEED (MIN)
Sets the minimum speed of the motor. The MIN Trimpot is factory
set to 0% of frequency setting. For a higher minimum speed,
setting, rotate the MIN Trimpot clockwise. See Figure 7-1.
Figure 7-1 Minimum Speed Trimpot Range
(Shown Factory Set to 0%
Frequency Setting)
7.2 MAXIMUM SPEED (MAX)
Sets the maximum speed of the motor. The MAX Trimpot is
factory set for 100% of frequency setting. For a lower maximum
speed setting, rotate the MAX Trimpot counterclockwise. For
a higher maximum speed setting, rotate the MAX Trimpot
clockwise. See Figure 7-2.
Summary of Contents for ID5601-EO