![Baldor ID5601-EO Installation And Operation Manual Download Page 29](http://html.mh-extra.com/html/baldor/id5601-eo/id5601-eo_installation-and-operation-manual_468808029.webp)
29
Figure 6-2 Motor Horsepower Selection
6.3 AUTOMATIC OR MANUAL START AND RESET
SELECTION (J3)
See Figure 6-3.
WARNING! AUTOMATIC START AND RESET: JUMPER J3 IS FACTORY
SET TO THE “AUTO” POSITION TO AUTOMATICALLY
START THE DRIVE WHEN THE POWER IS APPLIED AND
THE ON/OFF AC LINE SWITCH IS SET TO THE “ON”
POSITION.
WARNING! THE DRIVE WILL AUTOMATICALLY RESTART AFTER
FAULT HAS CLEARED. IF AN I
2
T OR SHORT CIRCUIT
FAULT OCCURS, THE DRIVE MUST BE RESTARTED BY
SETTING THE ON/OFF AC LINE SWITCH TO THE “OFF”
POSITION FOR A MINIMUM OF 5 SECONDS.
6.3.1 Manual Start and Reset
*
In Manual Start Mode, the drive must be manually restarted after
a fault has cleared using the optional Forward-Stop-Reverse
Switch. If a Short Circuit or I
2
t Fault occurs, the drive can be
restarted by setting either the On/Off AC Line Switch to the “OFF”
position for a minimum of 5 seconds or setting the Forward-Stop-
Reverse Switch to the “STOP” position.
*
Note:
The optional Forward-Stop-Reverse Switch must in installed in
order to use the drive for Manual Start operation.
Figure 6-3 Automatic or Manual Start and Reset Selection
Automatic Start and Reset
(Factory Setting)
(J3 Installed in “AUTO” Position)
Manual Start and Reset
(J3 Installed in “MAN” Position)
Summary of Contents for ID5601-EO