![Baldor ID5601-EO Installation And Operation Manual Download Page 14](http://html.mh-extra.com/html/baldor/id5601-eo/id5601-eo_installation-and-operation-manual_468808014.webp)
14
2. QUICK-START INSTRUCTIONS
Note:
This drive contains bus capacitors which must be reconditioned if the
drive has been in storage for over 1 year. To recondition the bus
capacitors, apply the AC line with the main speed potentiometer set to
zero for a minimum of 30 minutes.
See Figures 2-1, 2-2, 2-3, 2-4 and Chapter 5, Important Application
Information.
WARNING: HIGH VOLTAGE IS PRESENT IN THIS DRIVE. DISCONNECT
MAIN POWER BEFORE MAKING CONNECTIONS TO
THE DRIVE. TO PREVENT ACCIDENTAL CONTACT WITH
HIGH VOLTAGE, IT IS REQUIRED THAT THE COVER BE
PROPERLY INSTALLED AFTER ALL SETUP,
CONNECTIONS, AND ADJUSTMENTS ARE COMPLETE.
THIS REDUCES ELECTRICAL SHOCK HAZARD. FAILURE
TO OBSERVE THIS WARNING COULD RESULT IN
ELECTRICAL SHOCK OR ELECTROCUTION.
Note:
It is recommended that both Feed-Through Bushings (See Figure
2-4) be sued to connect the drive. If signal wiring (for the Run/Fault Relay
Output Contacts or for a remote Main Speed Potentiometer) is required, it
is recommended that the extra Feed-Through Bushing (supplied with
the drive) be used to replace the center Hole Plug. Standard 3/4” fittings
(not supplied) can also be used in lieu of the Feed-Through Bushings.
Figure 2-1 Quick-Start Connection Diagram
*For 115 VAC line, install jumper J1 (supplied).
Recommended Tightening Torque
lb-in (7), kg-cm (8)
Important:
You must read these simplified instructions before
proceeding. These instructions are to be used as a reference only and
are not intended to replace the details provided herein. You must read
the SAFETY NOTICES before proceeding.
Summary of Contents for ID5601-EO
Page 18: ...18 Figure 2 3 Drive Layout ...