7-10 Specifications
MN1902
7.1.16 Master (auxiliary) encoder input (X9)
All models
Unit
All models
Signal
RS422
Operating mode
A/B quadrature
Maximum input frequency
(quadrature)
MHz
2.5
Sampling interval
ms
Software selectable: 1, 2
Output power supply to encoder
5V, 100mA max.
7.1.17 Pulse and direction input (X9)
All models
Unit
All models
Pulse and direction signals
RS422
Input current
(5V input)
mA
1.2mA
Maximum input frequency
MHz
1.25
Sampling interval
ms
Software selectable: 1, 2