Basic Installation 3-33
MN1902
3.9.6 Switches 9 and 10 - RS232/RS485 select
Switch 9 is reserved for Baldor keypad selection.
Switch 10 selects RS232 communications (Off) or RS485/RS422 (On) the next time the
FlexDrive
II
is power-cycled.
3.9.7 Factory settings
If switches 1-4 are all in the On position and switch 8 is set to Off, the FlexDrive
II
will be reset
to its preset factory settings at power on (or whenever the processor is reset by
WorkBench v5).
CAUTION
: Use this function carefully - it will erase your drive setup information.
When using the SW1 DIP switches to reset the FlexDrive
II
to its factory defaults, all
parameters including the node number and serial communications baud rate will be reset.
In WorkBench v5, this means it will be necessary to rescan for the FlexDrive
II
(by starting a
new project) to enable communication. It will also be necessary to re-tune your motor and
drive.
On
1
Reapply
power.
1.
2.
On
2
On
3
On
4
FlexDrive
II
will
be reset to its
preset factory
settings.
3.
Off
8
Remove
power.
4.
Figure 20 - Resetting the FlexDrive
II
to its factory default settings
The Mint keyword
FACTORYDEFAULTS
can also be used to reset the FlexDrive
II
to its factory
defaults. However, it will not reset the node number or serial communications baud rate. See
the Mint help file for details.
Summary of Contents for Flex+DriveII
Page 1: ...FlexDriveII Flex DriveII Servo Controls SERVO DRIVE Installation Manual 10 02 MN1902...
Page 2: ......
Page 14: ...2 4 Introduction MN1902...
Page 68: ...4 20 Input Output MN1902...
Page 80: ...5 12 Operation MN1902...
Page 98: ...7 12 Specifications MN1902...
Page 106: ...A 8 Accessories MN1902...
Page 122: ...Index MN1902...
Page 124: ...Comments MN1902 Thank you for taking the time to help us...
Page 125: ......