Input / Output 4-9
MN1902
4.3.5 Digital outputs - X3
Location
Connector X3
Pin Name
Mint keyword
18 DOUT0
OUTX.0
19 DOUT1
OUTX.1
20 DOUT2
OUTX.2
Description
Three general-purpose optically isolated digital outputs.
Output current: 50mA maximum each output
Update interval:
Immediate - Software (Mint programs)
2ms -
DRIVEENABLEOUTPUT
,
DRIVEOKOUTPUT
and
GLOBALERROROUTPUT
functions
Programmable - PLC Task functions
Each optically isolated PNP output is designed to source current from the USR V+ supply as
shown in Figure 28. The maximum saturated voltage across any of the outputs when active is
1.0VDC, so they can be used as TTL compatible outputs. If the outputs are used to directly
drive a relay, a suitably rated flyback diode must be fitted across the relay coil, observing the
correct polarity. This is to protect the output from the back-EMF generated by the relay coil
when it is de-energized. The outputs can be written to directly using the Mint keyword
OUTX
(for example
OUTX.2=1
). The sense of the outputs can be configured in WorkBench v5, and
their states are displayed in the Spy window.
CGND
OUTX.
x
USR V+
FlexDrive
II
NEC PS2562L-1
DOUT0
Load
(Relay with
flyback diode
shown)
Pin 18
Pin 8
Pin 6
Figure 28 - X3 digital output circuit - DOUT0 shown
18
20
CGND 8
Summary of Contents for Flex+DriveII
Page 1: ...FlexDriveII Flex DriveII Servo Controls SERVO DRIVE Installation Manual 10 02 MN1902...
Page 2: ......
Page 14: ...2 4 Introduction MN1902...
Page 68: ...4 20 Input Output MN1902...
Page 80: ...5 12 Operation MN1902...
Page 98: ...7 12 Specifications MN1902...
Page 106: ...A 8 Accessories MN1902...
Page 122: ...Index MN1902...
Page 124: ...Comments MN1902 Thank you for taking the time to help us...
Page 125: ......