7.1.7 Digital inputs (X3)
All models
Unit
All models
Type
Opto-isolated DC inputs
Input voltage (Active high)
Nominal
Minimum
VDC
24
12
Input voltage (Active low)
Nominal
Maximum
VDC
0
2
Input current
(approximate, per input)
mA
5
Sampling interval
ms
2
Maximum pulse input frequency
(DIN4, pulse and direction mode)
MHz
1
Minimum pulse width
(DIN4/DIN5, pulse and direction mode)
ns
250
7.1.8 Digital outputs (X3)
All models
Unit
All models
Output current
(maximum, each output)
mA
50
Update interval
Software (Mint programs)
DRIVEOKOUTPUT
,
DRIVEENABLEOUTPUT
,
and
GLOBALERROROUTPUT
functions
PLC Task functions
Immediate
2ms
Programmable