Specifications 7-5
MN1902
7.1.5 Regeneration
115VAC
(Catalog number FDH
1
... / FPH
1
...)
Unit
2.5A
5A
7.5A
Switching threshold
VDC
on: 188-195, off: 183-188
Nominal power
(10% power cycle)
kW
0.25
Peak power
(10% power cycle)
kW
2.7
Maximum regeneration
switching current
A
RMS
10
Maximum load inductance
ì
H
100
*Note:
2.5A models (
FDH1
A02
...
and
FPH1
A02
...
) contain an internal 175
Ω
, 20W resistor.
5A models (
FDH1
A05
...
and
FPH1
A05
...
) contain an internal 90
Ω
, 40W resistor.
230VAC
(Catalog number FDH
2
... / FPH
2
...)
Unit
2.5A
5A
7.5A
Switching threshold
VDC
on: 373-383, off: 362-372
Nominal power
(10% power cycle)
kW
0.25
Peak power
(10% power cycle)
kW
2.7
Maximum regeneration
switching current
A
RMS
10
Maximum load inductance
ì
H
100
*Note:
2.5A models (
FDH2
A02
...
and
FPH2
A02
...
) contain an internal 175
Ω
, 20W resistor.
5A models (
FDH2
A05
...
and
FPH2
A05
...
) contain an internal 90
Ω
, 40W resistor.
230VAC
three-phase models
(Catalog number FDH
2
A
15
... / FPH
2
A
15
...)
Unit
15A
Switching threshold
VDC
on: 376, off: 365
Nominal power
(10% power cycle)
kW
1.0
Peak power
(10% power cycle)
kW
15
Maximum regeneration
switching current
A
RMS
40
Maximum load inductance
ì
H
100
Summary of Contents for Flex+DriveII
Page 1: ...FlexDriveII Flex DriveII Servo Controls SERVO DRIVE Installation Manual 10 02 MN1902...
Page 2: ......
Page 14: ...2 4 Introduction MN1902...
Page 68: ...4 20 Input Output MN1902...
Page 80: ...5 12 Operation MN1902...
Page 98: ...7 12 Specifications MN1902...
Page 106: ...A 8 Accessories MN1902...
Page 122: ...Index MN1902...
Page 124: ...Comments MN1902 Thank you for taking the time to help us...
Page 125: ......