TEMPUS III
- 52 -
O
Y
K
EN
Z
A
1
2
3
4
JP4
5
6
7
8
Input from electric system (220 VAC)
Contacts of
K2
Coin blocking
Output
(220VAC)
CONNECTOR Jp4
Pins
Comment
1-2
3-4
5-6
7-8
CONFIGURATION OF THE CONNECTOR JP4
Contacts of
relay K2
without voltage. If the
Tempus II
I has time,
They will be closed.
Control of total coin blocking. If they are bridged, no coin is admitted.
Power supply output of the load device (220 VAC with 6A-fuse
protection).
Power supply voltage of the
Tempus III
(220 VAC).
TOTAL COIN INPUT BLOCKING
The Tempus III has an exterior inlet for totally blocking coins that, when activated, sends the
coins directly to the coin return box.
In order to block all of the coins, pins 3 and 4 of connector JP4 have to be bridged. If these
pins are not bridged, the coins that are enabled by the program will be admitted.