User Manual UMAX030541. Version V1 70-116
3.4 MANUFACTURER OBJECTS
Index
(hex)
Object
Object
Type
Data Type
Access PDO
Mapping
2223
DO Blink Rate 1 Output
Line
ARRAY
UNSIGNED16
RW
No
2240
DO Digital Range
ARRAY
UNSIGNED8
RW
No
2241
DO Polarity
ARRAY
UNSIGNED8
RW
No
2300
AO Override Field Value
ARRAY
INTEGER16
RW
No
2330
AO Ramp Up
ARRAY
UNSIGNED16
RW
No
2331
AO Ramp Down
ARRAY
UNSIGNED16
RW
No
2340
AO Control Input Source
ARRAY
UNSIGNED8
RW
No
2341
AO Control Input Number
ARRAY
UNSIGNED8
RW
No
2342
AO Control Response
ARRAY
UNSIGNED8
RW
No
2350
AO Enable Input Source
ARRAY
UNSIGNED8
RW
No
2351
AO Enable Input Number
ARRAY
UNSIGNED8
RW
No
2352
AO Enable Response
ARRAY
UNSIGNED8
RW
No
2360
AO Override Input Source
ARRAY
UNSIGNED8
RW
No
2361
AO Override Input Number
ARRAY
UNSIGNED8
RW
No
2362
AO Override Response
ARRAY
UNSIGNED8
RW
No
2370
AO Feedback Field Value
ARRAY
INTEGER16
RO
Yes
2380
AO Output Frequency
ARRAY
UNSIGNED16
RW
No
2500
EC Extra Received Process
Value
ARRAY
INTEGER16
RW
Yes
2502
EC Decimal Digits PV
ARRAY
UNSIGNED8
RW
No
2520
EC Scaling 1 PV
ARRAY
INTEGER16
RW
No
2522
EC Scaling 2 PV
ARRAY
INTEGER16
RW
No
3yz0
LTyz Input X-Axis Source
VAR
UNSIGNED8
RW
No
3yz1
LTyz Input X-Axis Number
VAR
UNSIGNED8
RW
No
3yz2
LTyz Auto Repeat
VAR
UNSIGNED8
RW
No
3yz3
LTyz X-Axis Decimal Digits
PV
VAR
UNSIGNED8
RW
No
3yz4
LTyz Y-Axis Decimal Digits
PV
VAR
UNSIGNED8
RW
No
3yz5
LTyz Point Response
ARRAY
UNSIGNED8
RW
No
3yz6
LTyz Point X-Axis PV
ARRAY
INTEGER32
RW
No
3yz7
LTyz Point Y-Axis PV
ARRAY
INTEGER16
RW
No
3yz8
LTyz Output Y-Axis PV
VAR
INTEGER16
RO
Yes
3300
Logic Block Enable
ARRAY
BOOLEAN
RW
No
3310
Logic Block Selected Table
ARRAY
UNSIGNED8
RO
Yes
3320
Logic Output Process Value
ARRAY
INTEGER16
RO
Yes
3x01
LB(x-3) Lookup Table
Number
ARRAY
UNSIGNED8
RW
No
3x02
LB(x-3) Function Logical
Operator
ARRAY
UNSIGNED8
RW
No
3x11
LB(x-3) Function A Condition
1
RECORD
UNSIGNED8
RW
No