3.4.9 Object 2342h: AO Control Response
This object defines the response profile of the analog output FV with respect to the input
PV (as selected by objects 2340h/2341h.) Normally it will follow the profile shown in
Figure 5. However, in some cases the offset will be disabled (i.e. output at 0) when the
PV is below 7320h Scaling 1 PV or alternatively above the 7322h Scaling 2 PV. The
options for this object are listed in Table 8.
Object Description
Index
2342h
Name
AO Control Response
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
4
Default Value
4
Sub-Index
1h to 4h (x = 1 to 4)
Description
AOx Control Response
Access
RW
PDO Mapping
No
Value Range
See Table 8
Default Value
1 (Output OFF below Scaling 1 PV)
3.4.10 Object 2350h: AO Enable Input Source
This object defines the type of input that will be used to enable/disable the analog (or
digital) output as shown in the logic flowchart in Figure 5. The available control sources
on the CAN-4AOUT controller are listed in Table 5. Not all sources would make sense to
enable the AO, and it is the user’s responsibility to select a source that makes sense for
the application.
Object Description
Index
2350h
Name
AO Enable Input Source
Object Type
ARRAY
Data Type
UNSIGNED8