1h to 4h (x = 1 to 4)
Description
AOx Feedback Field Value
Access
RO
PDO Mapping
Yes
Value Range
Dependent on range (see Table 4)
Default Value
No
3.4.17 Object 2380h: AO Output Frequency
This object is used to set the frequency of the outputs. When the output is under
Frequency mode, it will be used to set duty cycle of the outputs.
Object Description
Index
2380h
Name
AO Output Frequency
Object Type
ARRAY
Data Type
UNSIGNED16
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
4
Default Value
4
Sub-Index
1h to 4h (x = 1 to 4)
Description
AOx Output Frequency
Access
RW
PDO Mapping
No
Value Range
1…25000 Hz
Default Value
25000
3.4.18 Object 2500h: EC Extra Received Process Value
This object provides an extra control source in order to allow other function blocks to be
controlled by data received from a CANopen® RPDO. It functions similarly to any other
writeable, mappable PV object.
Object Description
Index
2500h
Name
EC Extra Received Process Value
Object Type
ARRAY
Data Type
INTEGER16