User Manual UMAX030541. Version V1 64-116
Object Description
Index
6332h
Name
AO Decimal Digits FV
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
4
Default Value
4
Sub-Index
1h to 4h (x = 1 to 4)
Description
AOx Decimal Digits FV
Access
RW
PDO Mapping
No
Value Range
0 to 4
Default Value
3 [mv]
3.3.7 Object 6340h: AO Fault Mode
This object defines how an analog output shall response when a fault condition is detected
on any control input, as described in Table 11.
Object Description
Index
6340h
Name
AO Fault Mode
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
4
Default Value
4
Sub-Index
1h to 4h (x = 1 to 4)
Description
AOx Fault Mode
Access
RW
PDO Mapping
No
Value Range
See Table 11
Default Value
1 (Apply Pre-defined FV)