User Manual UMAX030541. Version V1 52-116
Sub-Index
3h
Description
Revision Number
Access
RO
PDO Mapping
No
Value Range
UNSIGNED32
Default Value
0x00010000
Sub-Index
4h
Description
Serial Number
Access
RO
PDO Mapping
No
Value Range
UNSIGNED32
Default Value
No
3.2.12 Object 1020h: Verify Configuration
This object can be read to see what date the software (version identified in object 1018h)
was compiled. The date is represented as a hexadecimal value showing day/month/year
as per the format below. The time value at sub-index 2 is a hexadecimal value showing
the time in a 24 hour clock
MSB
LSB
Day (in 1-Byte Hex)
Month (in 1-Byte Hex)
Year (in 2-Byte Hex)
00
00
Time (in 2-Byte Hex)
For example, a value of 0x30042014 would indicate that the software was compiled on
April 30
th
, 2014. A time value of 0x00001842 would indicate it was compiled at 6:42pm.
Object Description
Index
1020h
Name
Verify configuration
Object Type
ARRAY
Data Type
UNSIGNED32
Entry Description
Sub-Index
0h
Description
Number of entries
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2