User Manual UMAX030541. Version V1 85-116
it uses the same resolution as the received PV as defined in object 2502h, EC Decimal
Digits PV. This object must always be smaller than object 2522h EC Scaling 2 PV.
Object Description
Index
2520h
Name
EC Scaling 1 PV
Object Type
ARRAY
Data Type
INTEGER16
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
6
Default Value
6
Sub-Index
1h to 6h (x = 1 to 6)
Description
ECx Scaling 1 PV
Access
RW
PDO Mapping
No
Value Range
-32768 to 2522h sub-index X
Default Value
0
3.4.21 Object 2522h: EC Scaling 2 PV
This object defines the maximum value of the extra control source. It used as the Scaling
2 value by other functions blocks when the EC has been selected as the source for the
X-Axis data, i.e. as seen in Figure 4. There is no physical unit associate with the data, but
it uses the same resolution as the received PV as defined in object 2502h, EC Decimal
Digits PV. This object must always be larger than object 2520h EC Scaling 1 PV.
Object Description
Index
2522h
Name
EC Scaling 2 PV
Object Type
ARRAY
Data Type
INTEGER16
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
6
Default Value
6