4.
Initialization
4.1.
Initialization - phase 1
Choose INITIALIZATION from the main menu.
During the first phase of the initialization, the tuner settings required for the scan are made and the station
scanning is carried out. The tuners work independently from each other and after the same principle.
4.1.1.
DVB-S/S2/S2X
Click TUNER 1…8/12/16 to select one tuner.
Configure the needed settings for all tuners.
The frequency of the transponder is entered in the input field
Freq (MHz).
The frequency must be ≥ 1300 MHz, otherwise an error message appears.
The input fields
Low LNB LO Freq (MHz)
and
High LNB LO Freq (MHz)
correspond to the oscillator
frequencies of the LNB in low and high band. The default settings of the oscillator frequencies are
9,750 MHz for the low band and 10,600 MHz for the high band.
In the optional field
Polarisation
, you can switch from horizontal to vertical.
In the optional field
DiSEqC
, the DiSEqC command signals can be turned off or set to switch a DiSEqC-
enabled multi switch on the positions 1 to 4.
If required, the operating voltage for the LNB can be switched off via the optional field
LNB Power
.
If
multistreams
are to be received, then the
PLS mode
must be set to root or gold. In addition, the
correct
Stream ID
(three digits) and the
PLS code
(six digits) must be entered.
After all settings have been made, click SAVE & SCAN.
A rotating circle is shown during the scanning process.