Operation instructions | MK 8-0x | MK 16-0x | MK 8-2x | MK 8-0xN | MK 12-0xN
16
2022-07-27 | Technical improvements, changes in design, printing- and other errors reserved.
2.6.2.
Connection to DVB-T/T2 or DVB-C (MK 8-0x, MK 8-2x and MK 16-0x only)
Before connecting the antenna cabel, the LNB power has to be switched off (see 4.1.2 on page 23).
Active DVB-T antennas have to be supplied by an external power supply.
2.6.3.
RF Output
Install the device in compliance with the safety regulations defined by the EN 60728-11 standard.
Connect the output (RF OUT) of the device to the established distribution network. Use a high-shielded
coaxial cable with an F connector.
If you are using several devices, the outputs must be connected with suitable combiners.
There has to be used galvanic isolator between the output connector and antenna network in Sweden and
Norway state area.
2.7.
Connection to the Internet
2.7.1.
Connection via Ethernet switch to a router which is connected to the Internet