4.2.7.
PID-Remapping
Automatic PID remapping
If several programs within an output modulator contain packets that have the same PID, this can cause
interferences. Therefore these PIDs are re-mapped automatically.
In the example, both programs are assigned to modulator M1
(1)
. The IN PIDs 101 to 105 are identical for both
the upper program „Das Erste“ and the lower program „Eurosport“. Therefore, the PIDs are re-mapped in the
lower program and other IDs are automatically entered in the OUT PID column
(2)
.
Fixing PIDs
Fixing a PID prevents PIDs from being re-mapped.
Click on one of the programs.
The table with the packages opens.
For the PIDs that you want to fix, set the check mark in the FIXED column.
Click SAVE CHANGES.