Configuring 3.x Reader Firmware
46
750.001.003
Revised June 1999
© 1999 AXCESS
TM
Inc.
Jp
1
1
Jp
2
1
Jp
4
Jp
3
Jp
6
Jp7
1
Service Pin
Reset Button
Wiegand Connector
Serial/FTT Connector
Figure 18 Unilon card
Depending on how the card is set up, there may be a serial cable
connected to the top of the card and the jumper shunts may be in
different places.
IMPORTANT!
Do not press the Service Pin. If the Service Pin is
accidently pressed, cycle the power off and on to put the Reader into
a known state.
Viewing Unilon Card Information
Step 1:
Connect the Reader to a PC and access the Reader with a
terminal application. See the section
Configuring 3.x
Reader Firmware
, page 35, for instructions.
Step 2:
Press the reset button on the Unilon RX Card. The Reader
will display to the screen the firmware name, its revision
number and the jumper settings separated by dollar signs
( $ ).
For example, when pressing the reset button on a Unilon
RX Card, the following information may be seen on the
terminal screen:
200rx $Revision: 1.6 $Receive JP1=2-3 JP2=2-3
Step 3:
Press the reset button on the Unilon TX Card. The Reader
will display to the screen the firmware name, its revision
number and the jumper settings separated by dollar signs
( $ ).
For example:
200ltx $Revision: 1.5 $Transmit JP1=2-3 JP2 1-2