38
© 2008 Directed Electronics. All rights reserved.
Multi-level security arming
Multi-Level Security Arming is a feature that allows the user to select which of the
system's inputs or sensors will be active and which will be bypassed when the
system is armed. (See Table of Zones section of this guide.) Multi-Level Security
Arming can only be accessed from a standard configuration transmitter. Pressing
the arm button of the standard configuration transmitter again within five seconds
of arming the system will activate the Multi-Level Security feature. Each time the
arm button is pressed again, a different security level is selected. The different
levels of security are selected as follows:
Pressing
�������
one time: The siren chirps once. The system is armed.
Pressing
�������
a second time within five seconds: The siren chirps twice followed
by a long chirp. Zone Two is now bypassed.
Pressing
�������
a third time within five seconds: The siren chirps three times fol-
lowed by a long chirp. Zone Four is now bypassed.
Pressing
�������
a fourth time within five seconds: The siren chirps four times fol-
lowed by a long chirp. Zones Two and Four are now bypassed.
Pressing
�������
a fifth time within five seconds: The siren chirps five times followed
by a long chirp. All input zones, except the ignition, are now bypassed.
Summary of Contents for 5303
Page 22: ...22 2008 Directed Electronics All rights reserved WAIT TO START WIRE ...
Page 60: ...60 2008 Directed Electronics All rights reserved Relay satellite wiring quick reference guide ...
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ...N5303L 2008 07 Vista CA 92081 www directed com 2008 Directed Electronics All rights reserved ...