Network Zone Configurations
38
Zone 2 Clients (Indirect Connect) Configuration
www.avid.com/onlinesupport
.
A Zone 2 (indirect connect) configuration consists of group of clients connected to an Ethernet
switch with a 10-Gb port connected to an ISS located in the engine. The System Director also
connects to both subnets via both ISS modules using a 1-Gb port. Depending upon the switch
configuration, each client shown connected to the external switch is connected to one of the two
subnets through one of the two 10-Gb connections.
1 Gb Ports in Zone 1
ISS1000 and IXS1000 Switches
ISS2000 and IXS2000 Switches
Number
of ISIS
Engines
One System
Director
Two System
Directors
(failover)
One System
Director
Two System
Directors
(failover)
1
14
12
14
12
2
30
28
30
28
3
30
a
a. This is due to the use of IXS switches instead of an ISSs.
28
a
30a
28a
4
46
44
46
44
5
62
60
62
60
6
78
76
78
76
7
94
92
94
92
8
110
108
110
108
9
110
b
b. This is due to the use of two more IXS1000 switches instead of an ISS.
108b
126
124
10
126
124
142
140
11
142
140
158
156
12
158
156
174
172