16
ZK830 Counting Scale User Instructions
Indicator applications
3 Indicator applications
This indicator has three weighing applications that can be enabled through a password
protected menu. Only one application can be enabled at a time. The applications
available are:
l
Parts Counting
l
General Weighing
l
Checkweighing
3.1 First time power up
Upon first time power up you are given the choice of which application you want to use.
APP
appears on the screen. Press
SELECT
and use the
UNITS
or
key to scroll
through the choices. When the application you want to use is displayed, press
ZERO
.
That application will become active. Press the
TARE
key to start the normal mode for
the chosen application.
A password protected menu is used to change the active application.
To display active application name
You can display the active application name by doing one of the following:
l
Press and hold
SAMPLE/F1
until the numeric entry screen appears. Press
SAMPLE/F1
again to display the current application name.
Or
l
Cycle power and the current application name is displayed briefly on power
up.
3.2 Counting application
This section applies if the Count application is active.
3.2.1 Sampling methods
Dribble sampling is the default sampling method. Bulk sampling is also available. This
is set in a password protected Supervisor menu. Each type is defined below.
Dribble sampling definition:
When sample parts are being added to the scale they can be counted out slowly or, in
other words, dribbled onto the scale. A key press (
SAMPLE
key) is needed to finish the
sampling process. The piece weight is calculated and the count is displayed.
Key functions in different applications may vary. These will be noted under each
application.