ZK830 Counting Scale User Instructions
Indicator applications
3.
Place the container on the scale …
The scale should read 0.
4.
Place the items to be weighed on the scale.
To Clear a Tare
Remove all weight from the scale and press the
TARE
key. The display shows
tArEcLr
briefly, the tare is cleared and the display will change to gross mode.
3.3.4 High resolution weighing (if enabled)
To momentarily view a higher resolution weight value, press the
PCWT/F4
key. The
weight will be displayed with an extra digit of resolution for five seconds. This is only
available in the general weighing application.
3.3.5 Percentage weighing
If enabled you can use the scale to measure a percent weight gain or loss from a target
weight.
Clear the scale and be sure there is no active tare and press
ZERO
to zero the scale if
necessary.
Press the
SELECT
key repeatedly until the
%
annunciator is lit.
Place the target weight on the scale and press
SAMPLE/F1
. The display shows
0.0.
Add or remove weight until the display shows the desired percentage gain or loss.
When finished, you can return to gross weighing by pressing the
SELECT
key until the
GROSS
annunciator is lit.
3.3.6 Using setpoints
Setpoints are values (weight) at which outputs are triggered automatically. Outputs can
control relays connected to valves, lights, other machinery, etc. See the
for information on how to edit or enter setpoint values.
See the note below for an overview of how setpoints function.
If activated, setpoints behave differently in the different applications. See the table
below:
Below Value
Above Value
General App.
OFF
ON
Count App.
UNDER
ACCEPT
OVER
Checkweigher App.
UNDER
ACCEPT
OVER