E1070 Service Manual
29
3.4 Service Menu
Source (Analog or SensorComm)
1.
From the
SCALE
display, press the
key…
SourCE
is displayed. Use this item to choose between an analog or
SensorComm based system.
2.
Press the
key…
The current setting is displayed.
3.
Toggle between the Analog and Scom (North America only) choices using the
TARE
or
UNITS
key. When your choice is displayed press the
ENTER
key…
SourCE
is displayed.
CAP. (Capacity)
1.
With
SourCE
displayed, press the
UNITS
key…
CAP.
is displayed. Use this item to set the capacity for the scale.
2.
Press the
key…
The current capacity value is shown.
3.
Press
ENTER
to accept this value or key in a new capacity and press
ENTER
…
CAP.
is displayed.
DIV. (Division)
This item and the next one,
DP.POS.
, set the division size.
1.
With
CAP.
displayed, press the
UNITS
key…
div.
is displayed. This stands for the division value of your displayed
weight.
2.
Press the
key…
The current division value is shown.
3.
Scroll through the choices by using the
TARE
or
UNITS
key.
Pick from the following values; 1, 2, 5, 10, 20, 50, 100, 200, 500,
1/2, 2/
5, 5/10, 10/20, 20/50
.
The fraction choices (in bold) are for use as dual range divisions.
The first number is the division value for the first half of the
capacity and the second number is the division value for the 2nd
half of the capacity.
All of these capacities function in conjunction with the decimal place
position. For example, if you choose a division value of 5 and a decimal
position of 12345.6, your division size will be .5.
4.
When your choice is displayed, press
ENTER
.
div.
is displayed.
Summary of Contents for E1070
Page 1: ...Model E1070 Indicator Service Manual NORTH AMERICA AWT35 500106 Issue AF March 2010 ...
Page 6: ...6 E1070 Service Manual ...
Page 51: ...E1070 Service Manual 51 3 4 Service Menu Table 3 1 Printalbe Characters Chart ...
Page 146: ...146 E1070 Service Manual 8 Network Connections ...
Page 150: ...150 E1070 Service Manual 10 2 Complete Service Menu ...
Page 153: ...E1070 Service Manual 153 11 3 Wall Mount Application ...
Page 154: ...154 E1070 Service Manual 11 4 System Block Diagram ...
Page 155: ...E1070 Service Manual 155 11 5 Keypad Schematic and Power Supply Bd P N 60071 0016 ...
Page 158: ...158 E1070 Service Manual 11 8 I O External Calbe Identification Pin outs ...
Page 162: ...162 E1070 Service Manual ...
Page 163: ......