90
E1070 Service Manual
3
Using the Menus
28.
Press
UNITS
or
TARE
to toggle between
on
and
oFF
. If the indicator is being
connected to a SensorComm junction box and you want to send an email
when a SensorComm error occurs, select
on
. Otherwise select
oFF
. Press
either the
or
ENTER
key to accept your selection…
S-Com
is displayed.
29.
Press the
UNITS
key…
gHoSt
is displayed.
30.
Press the
key…
on
or
oFF
is displayed.
31.
If the indicator is being connected to a SensorComm junction box and
Ghosting is enabled and you want to send and email when a cell is ghosted,
select
on
. Otherwise select
oFF
. Toggle to your choice and press either the
or
ENTER
key to accept your selection…
gHoSt
is displayed.
32.
Press the
SELECT
key, then the
UNITS
key….
ProtcL
is displayed.
33.
Press the
key…
SMA
,
Enq
or
rdiSP
is displayed.
34.
Scroll through the choices using the
TARE
and
UNITS
keys. When the
desired choice is shown, press the
key to select it.
SMA
The SMA protocol over the Ethernet connection.
This is the exact same protocol used on the serial
ports. See the Service-Serial section of this manual
for details.
Enq
If
Enq
is chosen you will be prompted to key in a
polling character. This can be any value from 0 to
255. Example: if the desired polling character is a
carriage return, enter 13 for the polling character.
After the polling character is keyed in, press the
ENTER
key and the display will return to
ProtcL
.
When the polling character is received on the
Ethernet connection, the indicator will act as if the
key has been pressed (all of the formats-to-
print will be sent out of the configured port). If you
want the print format(s) to be sent back on the
Ethernet connection, the print formats must be
configured for tcpip1 (net1) or tcpip2 (net2). See the
Service-App and Service-Serial sections of this
manual for details on setting up the print formats.
Summary of Contents for E1070
Page 1: ...Model E1070 Indicator Service Manual NORTH AMERICA AWT35 500106 Issue AF March 2010 ...
Page 6: ...6 E1070 Service Manual ...
Page 51: ...E1070 Service Manual 51 3 4 Service Menu Table 3 1 Printalbe Characters Chart ...
Page 146: ...146 E1070 Service Manual 8 Network Connections ...
Page 150: ...150 E1070 Service Manual 10 2 Complete Service Menu ...
Page 153: ...E1070 Service Manual 153 11 3 Wall Mount Application ...
Page 154: ...154 E1070 Service Manual 11 4 System Block Diagram ...
Page 155: ...E1070 Service Manual 155 11 5 Keypad Schematic and Power Supply Bd P N 60071 0016 ...
Page 158: ...158 E1070 Service Manual 11 8 I O External Calbe Identification Pin outs ...
Page 162: ...162 E1070 Service Manual ...
Page 163: ......